{"id":1497,"date":"2025-10-20T14:07:13","date_gmt":"2025-10-20T14:07:13","guid":{"rendered":"https:\/\/dixieprecast.com\/?page_id=1497"},"modified":"2025-10-20T19:32:22","modified_gmt":"2025-10-20T19:32:22","slug":"helical-anchors","status":"publish","type":"page","link":"https:\/\/dixieprecast.com\/?page_id=1497","title":{"rendered":"Helical Anchors"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"1497\" class=\"elementor elementor-1497\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d14dd04 e-flex e-con-boxed syd-sticky-section-no e-con e-child\" data-id=\"d14dd04\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t\t\t\t\t<p class=\"e-a9dcb56-8344a5c e-paragraph-base\" data-interaction-id=\"a9dcb56\" data-interactions=\"&#x5B;&#x5D;\"  data-e-type=\"widget\" data-id=\"a9dcb56\">\n\t\t\t\t\t\t\t\tThe Dixie Precast Concrete DA-10 Helical Anchor offers a simple alternative to traditional foundations for communication towers, gate mechanism, and wayside signal mast applications. The helical foundations are installed in a matter of minutes with auger type equipment.\nThe Kelly Bar Adapter is placed on the equipment\u2019s kelly bar and attached to the top of the foundation. After attaching the foundation to the adapter, the foundation is simply screwed into the ground. The pilot point and helix of the foundation allow for quick and easy installation. With a few checks for level during the installation, the process is completed in a fraction of the time when compared to traditional foundations. The simple installation allows the associated labor costs to be greatly reduced.\nThe foundations are constructed completely of galvanized steel. The Helical Foundations are offered in 5\u2019, 7\u2019, and 10\u2019 lengths, all with standard 11 11\/16\u201d x 11 11\/16\u201d bolt spacing. Each foundation is supplied with 1\u201d x 8\u201d bolts, along with leveling nuts and associated hardware. Special sizes and applications are also available.\nThe Dixie Precase DA-10 Helical Anchors meet or exceed current AREMA Standards.\n\t\t\t\t\t<\/p>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7eb5a83 e-flex e-con-boxed syd-sticky-section-no e-con e-parent\" data-id=\"7eb5a83\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t\t\t\t<h2 \n\t\tdata-interaction-id=\"f264eec\" \n\t\tclass=\"e-f264eec-a1446c5 e-heading-base\" \n\t\t \n\t\tdata-e-type=\"widget\" data-id=\"f264eec\"\n\t\t\t>\n\t\n\t\t\tDA-10 Helical Anchor Documents\n\t\t<\/h2>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-57b85c2 e-flex e-con-boxed syd-sticky-section-no e-con e-parent\" data-id=\"57b85c2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-8589a0a e-con-full e-flex syd-sticky-section-no e-con e-child\" data-id=\"8589a0a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t    \t            <a\n            \t\t\thref=\"https:\/\/dixieprecast.com\/wp-content\/uploads\/2025\/10\/Dixie-Precast-DA-10-Anchor-Installation-Instructions.pdf\"\n        target=\"_blank\"\n            class=\"e-8b4a60b-76d8e63 e-button-base\"\n            data-interaction-id=\"8b4a60b\"\n            data-interactions=\"&#x5B;&#x5D;\"\n             data-e-type=\"widget\" data-id=\"8b4a60b\"\n        >\n            DA-10 Anchor Installation Instructions\n        <\/a>\n    \t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3e9a666 e-con-full e-flex syd-sticky-section-no e-con e-child\" data-id=\"3e9a666\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t    \t            <a\n            \t\t\thref=\"https:\/\/dixieprecast.com\/wp-content\/uploads\/2025\/10\/DixiePrecastStandardSpecifications.pdf\"\n        target=\"_blank\"\n            class=\"e-684549b-04ccf2a e-button-base\"\n            data-interaction-id=\"684549b\"\n            data-interactions=\"&#x5B;&#x5D;\"\n             data-e-type=\"widget\" data-id=\"684549b\"\n        >\n            Dixie Precast Standard Specifications\n        <\/a>\n    \t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e7435b4 e-flex e-con-boxed syd-sticky-section-no e-con e-parent\" data-id=\"e7435b4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t\t\t\t\n\t\t<img class=\"e-image-base \" \n\t\t\t\t\tdata-interaction-id=\"4db3270\" \n\t\t\tdata-interactions=\"&#x5B;&#x5D;\"\n\t\t \n\t\t data-e-type=\"widget\" data-id=\"4db3270\"\n\t\t\t\t\t\t\t\t\tid=\"995\"\n\t\t\t\t\t\t\t\t\t\t\t\tsrc=\"https:\/\/dixieprecast.com\/wp-content\/uploads\/2025\/10\/DA-10-Photo-7.jpg\"\n\t\t\t\t\t\t\t\t\t\t\t\twidth=\"1502\"\n\t\t\t\t\t\t\t\t\t\t\t\theight=\"1127\"\n\t\t\t\t\t\t\t\t\t\t\t\tsrcset=\"https:\/\/dixieprecast.com\/wp-content\/uploads\/2025\/10\/DA-10-Photo-7.jpg 1502w, https:\/\/dixieprecast.com\/wp-content\/uploads\/2025\/10\/DA-10-Photo-7-300x225.jpg 300w, https:\/\/dixieprecast.com\/wp-content\/uploads\/2025\/10\/DA-10-Photo-7-1024x768.jpg 1024w, https:\/\/dixieprecast.com\/wp-content\/uploads\/2025\/10\/DA-10-Photo-7-768x576.jpg 768w, https:\/\/dixieprecast.com\/wp-content\/uploads\/2025\/10\/DA-10-Photo-7-1000x750.jpg 1000w, https:\/\/dixieprecast.com\/wp-content\/uploads\/2025\/10\/DA-10-Photo-7-230x173.jpg 230w, https:\/\/dixieprecast.com\/wp-content\/uploads\/2025\/10\/DA-10-Photo-7-350x263.jpg 350w, https:\/\/dixieprecast.com\/wp-content\/uploads\/2025\/10\/DA-10-Photo-7-480x360.jpg 480w\"\n\t\t\t\t\t\t\t\t\t\t\t\talt=\"\"\n\t\t\t\t\t\t\/>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>The Dixie Precast Concrete DA-10 Helical Anchor offers a simple alternative to traditional foundations for communication towers, gate mechanism, and wayside signal [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1497","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/dixieprecast.com\/index.php?rest_route=\/wp\/v2\/pages\/1497","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dixieprecast.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/dixieprecast.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/dixieprecast.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dixieprecast.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1497"}],"version-history":[{"count":4,"href":"https:\/\/dixieprecast.com\/index.php?rest_route=\/wp\/v2\/pages\/1497\/revisions"}],"predecessor-version":[{"id":1560,"href":"https:\/\/dixieprecast.com\/index.php?rest_route=\/wp\/v2\/pages\/1497\/revisions\/1560"}],"wp:attachment":[{"href":"https:\/\/dixieprecast.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1497"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}